TECHNICAL DATA SHEET FOR MFV- MP -1040 |
| |
Performance Data : |
| |
|
| |
Discharge
(lpm) |
Pressure
(bar) |
Power |
RPM |
kilowatts |
Horsepower |
4000 |
10 |
125 |
168 |
3200 |
4500 |
7 |
105 |
140 |
2850 |
|
| |
|
| |
Discharge
(lpm) |
Pressure
(bar) |
Power |
RPM |
kilowatts |
Horsepower |
300 |
40 |
85 |
114 |
2950 |
|
| |
Suction Inlet:- 140 mm |
Priming Performance Range:- up to 8 meters |
Recommended Priming Speed:- 100 rpm to 2500 rpm |
Thermal Relief Valve Activation:- 55° C to 60°C |
Typical Dimensions:- |
|
| |
Length |
Width |
Height |
750 mm |
790 mm |
700 mm |
29.5 inches |
31.1 inches |
27.5 inches |
|
| |
*The Performance data stated above is observed at test conditions (3.0 meters suction lift at NTP conditions).
|
*For capacities other than stated above, please contact technical department.
|
| |
| |